Web12 de mar. de 2010 · Summary: Lightbulb should reveal section lines that "hide at scales coarser than" Description: Lightbulb should reveal section lines that "hide at scales coarser than" How Used: It would be nice if the light bulb could reveal section lines that are hidden by the "hide at scales coarser than" function. Feature Affinity: Settings - Views … Web8 de nov. de 2011 · January 23, 2014, 12:01 PM. It turns off the visibility of the view marker at scales above the stated value. For example you want to be able to see section marks and elevation marks on a floor plan view (1/8"=1'-0") but typically do NOT want to see those same marks in a site plan view (1"=20'-0"). The "hide at Scales" setting controls this ...
Section lines in sheets : r/Revit - Reddit
Web7 de fev. de 2024 · You can see that I can do that for sections as well. So if I click on this section here, you can see in the Properties Panel again I can go to "Hide at scales coarser than" and again this view is set to 1/4" = 1' - 0" so I would just need to set it to a scale larger than that. So let's set it to 3/8" = 1' - 0" and then you'll see it disappear ... Web19 de set. de 2024 · Issue: When trying to change the scale of a view or other settings like detail level, the settings are grayed out and inaccessible. Causes: A view template … incarcerated internal hernia
Hide at scales coarser than FOR PLANS! - Autodesk Community
Web9 de dez. de 2010 · Alfredo Medina. What about if, on your 1/4" plan view, you create just a callout view of the stairs. Then on that other view, at 1/2", you make all the section marks you need, to create the other views. Those section marks will be smaller and will be set to "Hide at scales coarser than: 1/2 = 1'-0", so they won't affect the main 1/4" view. Web16 de fev. de 2024 · When switching views, some section markers do not show up in associated views of the same level. Section markers are invisible in the plan view. The "Hide at scales coarser than" parameter setting in the section marker family prevents the marker from being displayed in the current view. Hide at scales coarser than Confirm issue is … WebWhen the Show in value is Intersecting Views, you can change the value of the Hide at scales coarser than parameter. As a result, Revit LT displays the callout tag in any views that intersect the parent view perpendicularly, as long as the view scale is more detailed than the scale specified by Hide at scales coarser than. in china during the 1970s there was a